| OPERATING ENVIRONMENTAL DATA | |
|---|---|
| Max. Heat Rejection to Air (Shaker) | 0.27 kW |
| Max. Heat Rejection to Air (Amplifier) | 0.45 kW |
| Max. Heat Rejection to Air (Blower) | 0.64 kW |
| Working Ambient Temperature * | 5 ~ 35 °C |
| Working Ambient Pressure | 0.1 MPa |
| Relative Humidity (Non-Condensing) | ≤ 80% |
| Max. Acoustic Noise | 92 dB |
| Temperature Range of Air Flow at Shaker Inlet | 0 ~ 35 °C |
| Air Line Supply Required (Compressed Air Supply) | 6.9 bar |
| Input Voltage (Standard) | 380 VAC, 50 Hz, 3 Phase |
| Power Requirements | 7.5 kVA |